4.2.1. The control of a cover of a broad tank and a radiatorThe cooling system works under superfluous pressure. The cover of a broad tank has a spring, the valve which opens at superfluous pressure 1,3–1,5 атм. At an elevated pressure the temperature of boiling of a liquid exceeds 100 With.
For the cover control it is necessary to have special опрессовочный the pump. It is screwed on a cover (fig. 99) and put in action before valve opening. It should occur before achievement of the specified pressure. If it not so it is necessary to replace a tank cover.
|
Fig. 99. Опрессовка covers of a broad tank
|
Using the same опрессовочный the pump, it is possible same way to check up all system of cooling on presence of leakings. For this purpose the pump is connected to a broad tank. Superfluous pressure lead up to 1,0 атм and check on a manometre that pressure keeps not less than 2 minutes If it does not occur, cooling system негерметична.
|